Bathford Energy Group Thermal Imaging Project 2013/2014

  Bathford Energy Group (BEG) has recently completed their write-up of their first year of thermal imaging. Their project was run in conjunction with Transition Bath. During the course of the winter they surveyed 15 homes, identifying many common issues to both old and new homes. Identification of common issues The common sources of heat […]

Thermal Imaging: Heat from Radiator seens from outside of Gerogian house

Thermal Image of a Radiator from outside a building

This radiator is visible from outside of Georgian home in Bath before a radiator reflector was installed. This issue is seen on many older homes in Bath which have solid walls which easily conduct heat to the outside world. A radiator reflector can be fitted in 2 minutes for as little of £3 and save […]

Thermal Imaging: Draughty door

Draughts around outside doors

Draughts around outside doors is a common problem in many, particularly older properties Example 1 In this property there are draughts around the bottom and sides of the door, and even a vertical split in the wooden inset panel which was not visible with out the thermal imaging camera. Potential solutions in this case include: Applying […]